4
Output
AES/EBU Digital Audio Output
Number of Outputs
Output Amplitude
Output Connector
Silence Signal (DARS grade 2) Output
Number of Outputs
Output Amplitude
Output Connector
• 48 kHz Word Clock
Number of Outputs
Output Amplitude
Output Connector
Signal Specifications
• Specifications
4 (2-channel output)
1 Vp-p ±0.1 V (into 75 )
BNC
1 (2-channel output)
1 Vp-p ±0.1 V (into 75 )
BNC
1
1 Vp-p ±0.1 V (into 75 ), 5 V CMOS, selectable
BNC
ANSI S4.40 (AES3-1992), AES 11-1997
SMPTE 276M, AES-3id-2001
Function
• Sampling Frequency
• Resolution
• Preemphasis
• Frequency
• Level
• Audio Click
• Output ON/OFF
• Timing
Variable Range
48 kHz (sync to video signal)
20 bits, 24 bits, selectable
OFF, 50/15 µs, CCITT, selectable (CS bit can only be
selected.)
50, 100, 150, 200, 250, 300, 400, 500, 600, 750, 800,
1.0 k, 1.2 k, 1.5 k, 1.6 k, 2.0 k, 2.4 k, 3.0 k, 3.2 k,
4.0 k, 4.8 k, 5.0 k, 6.0 k, 8.0 k, 9.6 k, 10 k, 12 k, 15 k,
16 k, 20 kHz, silence
-60 to 0 dBFS (settable in 1 dB steps)
1, 2, 3, 4 sec, none
Selectable
±1 AES/EBU frame
Settable in 512 fs (24.576 MHz) steps
*The timing can be varied with respect to the Video
Unit installed in the LT 443D mainframe.
The settings are common to the digital audio, silence
and word clock signals.
*Frequency, level, and audio click can be set to each
channel.
Other items (except timing) can be respectively set to
the 2-channel output.
Installing the LT 443D-DA Digital Audio Unit in the LT 443D
mainframe can output AES/EBU digital audio signals (four
systems), silence signals (one system), and 48 kHz word
clock signals.
The AES/EBU signal characteristics (e.g., output level, fre-
quency) can be independently set for each output system.
The sampling frequency is synchronized with the video sig-
nal of plug-in unit installed in the mainframe.
Test Signal Output
• Format
• Pattern
• NATURAL Picture *5
• APL
MODE
Time Interval
• ID Charactor
Number of Characters
Size
Display Position
Blinking
NTSC, NTSC+REFERENCE *2, NTSC+ID *3, NTSC+REF-
ERENCE+ID *2 *3, NTSC+SETUP, NTSC+SETUP+REF *2,
NTSC+SETUP+ID *3, NTSC+SETUP+REF+ID *2 *3, PAL
*4, PAL+REFERENCE *4 *2
*2 REFERENCE and REF denote Field Reference.
*3 ID denotes 10 field ID.
*4
The 25-Hz offset subcarrier is used for the PAL system.
COLOR BAR 100%, COLOR BAR 75%, EBU COLOR BAR,
BBC COLOR BAR, SMPTE COLOR BAR, FLAT FIELD
100%, FLAT FIELD 50%, FLAT FIELD 0%, CROSSHATCH
1, CROSSHATCH 2, LINE SWEEP 100%, LINE SWEEP
60%, MULTIBURST 100%, MULTIBURST 60%, SHAL-
LOW RAMP, 10 STEP, MOD 10 STEP, RAMP, MOD RAMP,
MONOSCOPE, RED RASTER, WINDOW, PULSE & BAR
Up to five screens of 24-bit full color BMP file can be
simultaneously switched.
APL OFF, APL HIGH, APL LOW, APL(BOUNCE), BOUNCE
APL (BOUNCE) is switched at a preset time interval
for APL HIGH and APL LOW.
BOUNCE is switched at a preset time interval for
FLAT FIELD 100 % and FLAT FIELD 0 %.
1 to 20 seconds (settable in one second steps)
Up to 20
32 x 32 dots, 64 x64 dots, selectable
Arbitrary position on the screen.
OFF, 1 to 10 seconds (settable in one second steps)
Simple Motion Picture Function
Direction
Speed
• Timing Variable
H-PHASE
V-PHASE
F-PHASE
• Number of Outputs
Black Signal Output
• format
• Output Signal
• Format
• Timing Variable
H-PHASE
V-PHASE
F-PHASE
• Number of Outputs
• Signal Level
Horizontal Drive Pluse Output
• Format
• Signal Level
• Signal Polarity
• Timing Variable
H-PHASE
• Number of Outputs
Vertical Drive Pluse Output
• Format
• Signal Level
• Signal Polarity
• Timing Variable
V-PHASE
• Number of Outputs
8 directions (up, down, left, right, and combinations)
H: 0 to 256 dots in 4 dot steps
V: 0 to 256 lines in 2 line steps
(Pattern can be scrolled in field time steps.)
*5 The Option LT 443D-70 should be installed in the
mainframe to enable this function.
The timing of OUTPUT 1 and 2 can be varied simultaneously.
Up to ±1 line-1 dot
Up to ±1 frame-1 line
NTSC:Up to ±5 frames
PAL: UP to ±2 frames
2
Depends on the test signal format. (Supports the field
Reference and 10 field ID)
Analog black burst
The timing of OUTPUT 1 and 2 can be varied simultaneously.
Up to ±1 line-1 dot
Up to ±1 frame-1 line
NTSC:Up to ±5 frames
PAL: UP to ±2 frames
2 Systems (one each)
1 Vp-p (into 75 )
Depends on the test signal format.
2 Vp-p (into 75 )
Negative
Up to ±1 line-1 dot
1
Depends on the test signal format.
2 Vp-p (into 75 )
Negative
Up to ±1 frame-1 line
1
The LT 443D-CS Analog Composite Unit adds the
NTSC/PAL analog composite signal output capability to
the LT 443D mainframe. Various functions (e.g., ID
character, simple motion pictures, embedded audio,
NATURAL picture pattern *1) are provided.
*1: The NATURAL picture function is only usable when
the Option LT 443D-70 is installed in the mainframe.
LT 443D-DA DIGITAL AUDIO UNIT
LT 443D-CS ANALOG COMPOSITE UNIT
Plug-In Unit For LT 443D
Plug-In Unit For LT 443D
Leader Instruments Corporation
6484 Commerce Drive
Cypress, CA 90630
www.LeaderUSA.com
Tel. : 1 (714) 527-9300
Fax.: 1 (714) 527-7490
Page view 3
1 2 3 4

Comments to this Manuals

No comments